877 karma · joined February 26, 2015
[1] https://austral-lang.org/ [2] https://austral-lang.org/spec/spec.html
If the author is around, I notice in the README you mention the GNU units program, which I use quite a bit. I'm curious if you've made any notable divergences from it?
* carbon removal credits are a subset of carbon credits
* they are generally considered higher-quality than most other credits (which are "avoided emissions"). This is because, for example, turning on a direct air capture machine, is clearly something that would not happen without the sale of carbon credits.
* there's not always a clear line between carbon removal credits and non-removal (ie "avoided emissions").
* unfortunately the carbon credits that have come under the most fire (nature-based solutions like forestry) are also, technically, closer to being "carbon removal" -- and some sellers play up that ambiguity, to their advantage.
> "it's like no one even read 'The Tyranny of Structurelessness,'" said an engineer who had recently read The Tyranny of Structurelessness.
However note the difference between carbon offsets vs carbon removals. I don't know what kinds of offsets Google bought but given that they started buying them >15 years ago, they were probably not removals.
> People have this aspirational idea of building a vast, oppressively colossal, deeply interlinked knowledge graph to the point that it almost mirrors every discrete concept and memory in their brain. And I get the appeal of maximalism. But they’re counting on the wrong side of the ledger. Every node in your knowledge graph is a debt. Every link doubly so.
2. That 6% is based on the most recent IPCC report which estimates 1.4 GT from HFCs, and another ~1.4 from CFCs+HCFCs, so 2.8 total. OWID seems to get its data from climatetrace, I haven't dug into their data, but if I'm reading that correctly it looks like that is only energy usage from manufacturing, rather than direct emissions of the gases. Looks like maybe this breakdown just ignores refrigerants, which is unfortunately common.
1. A trial burn done by an independent lab to make sure that under normal operating conditions, when destroying refrigerant the levels of those + other chemicals are below certain thresholds
2. automatic monitoring and shutoff mechanisms if the kiln deviates from normal conditions
1. Methane is 1900 ppb in the atmosphere[1], refrigerants overall are ~12.5 ppb -- so a lot less out there to detect. 2. I think methane leaks tend to be from single, continuing, large point sources -- coal mines, oil wells -- whereas refrigerants are usually from these distributed small point sources which happen once. So by the time you detect it it's too late to intervene.
[1] https://www.noaa.gov/news-release/increase-in-atmospheric-me...
1. Already operates at negative pressure with a high enough temperature and long enough residence time 2. Alkaline environment neutralizes the HF and HCl that are produced when the refrigerant burns. 3. Already consuming massive amounts of energy so the marginal energy use is negligible. 4. Allows use to use an existing facility instead of building our own -- great for developing countries where building infra is harder (but cement plants are everywhere).
[1] https://ozone.unep.org/sites/default/files/2019-04/TEAP-DecX...
In theory, reclaiming gases that are still unrestricted for production/import is at least as good as destruction from a climate perspective. However, virgin refrigerant is really cheap until import bans take hold -- so there is never a point where it is both economically worthwhile and impactful for climate. In theory you could use credits to boost the economics around reclaim but you end up with a very messy additionality story. My sense is that most reclaimers are very low-margin or even loss leaders for the companies that produce/sell the gas!
Anyway the short answer is that it's harder for us to figure out in this first push, but we do intend to look into it more closely as we expand.
1. Scrappers likely don't have the skills, equipment or inclination that AC technicians do.
2. Those self-contained units typically have a lot less refrigerant than the split AC systems (or large chillers) we see, which require venting in order to remove once installed. A refrigerator might have only 30 grams of charge, vs a split system with 2-3 kg.
Many companies are certainly looking to buy the cheapest credits they can find but there are promising indications that things are changing, led by companies like Stripe and Shopify.