Anecdotally, I see my CO2 levels hover around 600ppm inside even over night.
You see why this is a problem?
We even saw schools where the classrooms were not able to drop to ambient levels over the whole unoccupied weekend because the ppm levels on Friday afternoon were beyond 3000ppm.
The automatic baseline calibration period of some of the NDIR CO2 sensors can actually be adjusted through the software. I believe the Aranet allows that and also we do have that feature on the AirGradient dashboard. So you can switch it to a much longer period or switch it off completely.
There is also another thing: In multi-tenant buildings you may have others airing out their apartments which means you will not get ambient levels, but elevated ones due to added CO2 from the other apartment(s). For example, I see >500 ppm CO2 then. Also, even the ambient levels are not always the same; I have seen values between 416 and 432 ppm depending on the day, wind, and other factors (living in a larger city).