A sealed water loop where any plumber and most DIYers could manage would be miles ahead in both reliability and accessibility.
A sealed water loop where any plumber and most DIYers could manage would be miles ahead in both reliability and accessibility.
Even with more reliable brazed connections, modern heat pumps are very sensitive to contamination of the refrigerant lines. Brazing must be done with utmost care not to overheat the copper, and nitrogen gas needs to flow through the pipe at specific volumes to prevent carbon deposits that can decrease the longevity of the system. Any damage caused by improper brazing is largely invisible (inside the pipe) and the process is time consuming and precise; in exact opposition to the incentives an HVAC installer to get it done quickly.
Not to mention, installing them without an EPA 608 certification is technically illegal. MrCool and others that use them are relying on the EPA being understaffed and unlikely to pursue homeowners, but their stance on it is perfectly clear:
"Is technician certification required to install an R-410A mini-split?
Yes. Adding or removing refrigerant from a mini-split as part of installation, and/or connecting or disconnecting hoses or pre-charged lines requires a section 608 technician certification. Activities reasonably expected to violate the integrity of the refrigerant circuit include but are not limited to: Attaching or detaching hoses and gauges to and from the appliance; adding or removing refrigerant; adding or removing components; and cutting the refrigerant line."
https://www.epa.gov/section608/epas-refrigerant-management-p...
well, i run my through crawlspace. had only a small extra loop. in crawlspace.
>They're also much more expensive,
per unit - yes. but... if you doing to diy mini-split not with precharged lineste, you need vacuum, refrigerant and probably license to buy it. it raises cost and make it viable if you plant to install multiple units (have coworkers that did it). if you want to get it professionally install, than in addition to ~$1.4k for 2ton unit you look into $6k-$8k for labor. Those were prices year ago for install in garage with 240v line connected to 40amp breaker available at install location.
>Not to mention, installing them without an EPA 608 certification is technically illegal.
technically, i guess much of the work done by home owners must be done by certified professionals and get approvals and inspections.