Even with the Bosch library and their calibration the values seem rather odd at times
Even with the Bosch library and their calibration the values seem rather odd at times
What they are good at is detecting spikes, e.g. from cleaning liquids, desinfection etc. but I would not trust the absolute value at all.
The big sensor manufacturers recognized that and newer generations of the Sensirion sensors are now just displaying an "index" instead of absolute measurements.
How are companies like Bosch allowed to pass this crap off as functional? They don't meet even basic fitness for purpose criteria.
Another example was when I opened my window in my office. CO2 immediately dropped off (15:42 timestamp): https://twitter.com/akoutmos/status/1443233937015418891/phot...
> additional meters or sensors
I've got a CCS811 as well but no luck yet. Acquired 2nd hand so unsure if broken from shipping or I'm being stupid with code or I broke it while soldering
Are you seeing the same behavior?