The answer seems to me unambiguous when considering the normative language in § 4.2.1.1:
> The standard external cable connector assembly must not have a wire on pin 20, DP_PWR.
...in conjunction with the normative definition of trickle power per § 1.4 (my emphasis):
> Power for Sink Device that is sufficient to let the Source Device read EDID via the AUX CH, but insufficient to enable Main Link and other sink functions. For sink to drive the HPD signal high, at least the trickle power must be present. The amount of power needed for the trickle power is sink implementation specific.
(To be sure, Figure 4-23 per DP v1.1a is single-slot PCI "Panel Cut Out Reference Dimensions", so unsure what was meant to be conveyed there).
> Note that EC demands that electronics put in stand-by / "off-mode" may not consume more than 0.5 W of wall power.
...which is ~150 mA at 3.3 V nominal. Even generously derating 30% to account for ballpark efficiency losses, we're still talking > 100 mA budget to support an explicitly constrained requirement. I mean asserting HPD in the worst case is apparently a 36 uA affair.
Anecdotally, I haven't encountered the issue despite a bias towards DP (on advise from a friend in compliance test over a random beer discussion on radiated emissions performance); all my setups discriminate to either dual U2415 or dual U2412M as a matter of personal preference.
Just thought I'd remark in passing because VESA specs never really struck me as being technically egregious in its ambiguity.