The Sylmar grounding system is a line of 24 silicon-iron alloy electrodes submerged in the Pacific Ocean at Will Rogers State Beach[4] suspended in concrete enclosures about one meter above the ocean floor.
The grounding system at Celilo consists of 1,067 cast iron anodes buried in a two-foot trench of petroleum coke, which behaves as an electrode, arranged in a ring of 2.02 mi (3,250.87 m) circumference at Rice Flats (near Rice, Oregon), which is 6.6 mi (10.6 km) SSE of Celilo.
And even more interesting is they are replacing/replaced it! https://www.circlingthenews.com/terminus-of-sylmar-ground-re...
- HVDC uses voltages between 100 kV and 1,500 kV.
- HVDC can be cheaper for 500+ mile runs
- HVDC allows power transmission between unsynchronized AC transmission systems
- Recent advances make UHVDC feasible (800kV+)
AC won because transformers are relatively simple and can change AC voltage, but we can now build stuff to change AC voltage too.
We are a long way of seeing this setup used outside very special applications, AC might no longer have a natural advantage but the benefits of DC are too small to justify the massive investments and research required.
Though, it can certainly be argued that a single home-wide rectifier and smart DC wall sockets could improve efficiency and safety. You could have things like negotiated power up, ground insulation, cheaper and more efficient light bulbs and appliances etc.
Or you could build a 2 wire (or 4, 6 ...) DC line with complementary polarity that would carry more power due to skin effects. If the negative and positive loads are balanced, the currents though the earthing wire cancel out.
• No frequency matching issues between systems.
• DC systems appears as an open circuit to AC systems, limiting the spread of faults.
• Less expensive towers and wires.
• No reactive losses.
• No line length limits. Apparently AC has problems with lines longer than half a wavelength (2500 km or 1500 miles).