This is about as interesting as pointing out the fact that an ultrasound picture of a baby isn't an "actual picture", since we use sound instead of light to make the image.
This is about as interesting as pointing out the fact that an ultrasound picture of a baby isn't an "actual picture", since we use sound instead of light to make the image.
The first one was built in 1981, but one could have been built in the 1950s. Piezoelectric crystals were known. Raster scanning circuits were known. Feedback circuits for controlling the height were known. The tricks for making one-atom sharp points were not known, but the earliest STMs just stretched out a tiny platinum wire until it broke, and sometimes you got a one-atom point.
Hobbyists have built STMs.[1] It's simpler than building a 3D printer.
Surprisingly easy.
For really cool stuff, check out the CO functionalized tip AFM coming out of IBM in Zürich: https://www.zurich.ibm.com/st/atomic_manipulation/pentacene....
The AFM I used was mainly for teaching the concepts, so they wanted simple, cheap, low risk => strong NaOH was out.
The technique back then was, somehow, cutting at about 45° angle and twisting the pliers to make this angle go to zero while cutting/pulling. Then you had to put the tip in the machine and do test images to see whether the tip was good. Usually it wasn't, so you tried again. Finally you got a perfect tip, and maybe got two or three good images before you messed up the tip (from being a noob).
Getting pictures of atoms is nice, but sometimes you want to image molecules, especially organic ones (tricky to do in a STM).
Also, what would the shape of the tip look like if you drew it? I'm wondering what kind of general angles the surface has. Is it like a cone with a single atom at the tip? What kind of slope?
A good tip could be just about anything, from a nice cone to really jagged. One problem was any of the methods one has to view the tip can't actually resolve the single atom that is doing the imaging.
Dumb question .. I get that the needle scans a surface and you get the quantum tunneling effect between the atom you are "looking at" and the tip of the needle. What I don't get is how one figures out depth. For each X,Y position, do you just keep going down until you touch something, and then move up, and go to the next position? If so, apart from the issue with 1 atom tip, I imagine the next problem would how to increment X and Y by 1 atom.
P.S. I think some of the marketing put out on these things really confuses the issue. Sure .. it gets people excited about science but it gives people the wrong intuition. As a non-physics person, I got a lot out of this article.
This means that you're getting a "pseudo-height" map - if you had a surface with 2 types of atoms, both the same size, but with different tunneling barriers, you would see them appear to be different sizes.
High RF gains are easier to get than DC gains; you can filter out everything but the frequency of interest and reduce noise. That's basically how radios amplify weak signals. But I don't think you can run an STM on RF.
Ultrasounds also are pictures, but not photographs.
[1] https://physics.aps.org/featured-article-pdf/10.1103/PhysRev... (open access)
I do know how an ultrasound image works, and I had some basic knowledge about scanning tunneling microscopes, but this article - and the many links in it - were definitely worth my time reading.
I'm also curious -- but I wonder, would this allow for imaging anything that a scanning electron microscope can't?