> The clock reference, in other words the heart beat of this clock comes from the AC outlet.
Maybe it's really a 12VAC adapter?
But later...
> The clock reference, in other words the heart beat of this clock comes from the AC outlet.
Maybe it's really a 12VAC adapter?
Planned U.S. Power System Experiment Means Some Clocks Will Speed Up
http://spectrum.ieee.org/tech-talk/energy/the-smarter-grid/p...
Because if it did, then at least in the US, the 60Hz grid frequency is no longer a 'good' stable time-of-day clock reference.
Anecdotal evidence (my own old 60Hz line-synced alarm clock) prior to this experiment kept very good time (drift of 1-2 minutes over a year or more). Ever since this announcement, it has drifted fast such that I need to reset it about once a month for it to be reasonably accurate. And the drift now after a month or two is on the order of 5+ minutes.
http://www.maximintegrated.com/en/app-notes/index.mvp/id/199...
> Toward the end of the day the power company speeds up/slows down the frequency as needed so the total cycles in a given day is 5,184,000
That's incredible! I had no idea it was that accurate.
https://www.youtube.com/watch?v=slDAvewWfrA
This is about how the UK National Grid manage power availability at peak times. Over here we're running 50Hz rather than 60, but one of the key goals is to keep the grid frequency as close to 50Hz as possible.
At around 2m15s into the clip they lose power from a French on-demand provider and the frequency takes a "nose-dive" to 49.6Hz causing the operator to call on backup from a Welsh hydro-station to keep up with demand.
Theoretically in the UK we should get 4,320,000 cycles per day, but I suspect it's probably + or - 3 cycles. Unless of course it eventually balances out over the course of several days.
Happy to be corrected though.
When I first discovered that this was how grid demand was managed, stood in a UK National Grid control centre next to my brother who was interning for them, I was amazed.
https://www.entsoe.eu/fileadmin/user_upload/_library/publica...
Page P1-29, Definition D-D1, Tolerated Range of Discrepancy
A discrepancy between SYNCHRONOUS TIME and UTC is tolerated
within a range of ±20 seconds (without need for time control
actions).
And corrective action is to change the global-grid setpoint for frequency (of 50Hz) up or down by 0,01 Hz (i.e. 1sec difference in time shown on a clock / 5000 seconds of real time). So the system allows for ±20s·50Hz=1000 cycles of deviation until corrective action starts, and allowing for some time until the system reacts, that means that the clock might be off by ±30s in reality (the last one is a guess by me).But it's part of a much more elaborate scheme with several control-loops taking care of different things, the timing is only the global, outermost, regulation. All this makes much more sense, once one has realized that phase between two parts in the grid is the main controlled variable to determine flow of energy, so this document may appear to be quite obscure and strange to most people.
EDIT: corrected my math.
ADD: And, obviously, "Time Nut" Tim van Baak has a plot on the topic. For the US ;-). http://leapsecond.com/pages/mains/
With an unsmoothed rectified supply you get a nice "pulsed" input anyway:
http://falstad.com/circuit/#%24+1+5.0E-6+1.8479586061009856+...
A) would be easier. :)