And it won't even work during some of the coldest winter weeks when you _really_ need it to work.
Maybe I would consider it if I was in, like, Nevada or somewhere.
And it won't even work during some of the coldest winter weeks when you _really_ need it to work.
Maybe I would consider it if I was in, like, Nevada or somewhere.
Mine struggles if it gets below 30, and might as well not exist below 10. They're not great at low temps.
Mitsubishi hyper heat is indicative of a contemporary inverter design - 100% efficiency to -5f: https://www.mitsubishicomfort.com/articles/mythbusters-heat-...
At -5°F? Hell no!
At +5°F, they rate their own equipment to have a 2.0 CoP.
https://mylinkdrive.com/viewPdf?srcUrl=http://s3.amazonaws.c...
* https://ashp.neep.org/#!/product/156605/7/25000/95/7500/0///...
An LG unit with 2.4 at -4F/-20C:
* https://ashp.neep.org/#!/product/29688/7/25000/95/7500/0///0
Searchable database of cold climate air source heat pumps (ccASHPs):
Though it’s worth noting that that first 2 ton rated unit is putting out 0.5 tons (6k BTU/hr) at that temp and rating.
That’s not going to be particularly helpful for a structure that needed 24k BTU/hr during warmer temps, meaning the owner of the unit is likely mixing in a lot of 1.0 BTUs to meet the heat loss at -13°F.
I just did a quick search for "all" units and sorted the result list/table by COP@5F. If one was actually shopping/designing a solution then a more nuanced search criteria would be used.
Further, you'd probably want to do a (US ACCA) Manual J calculation to first determine how much energy is needed (j = joules)
* https://www.youtube.com/@HomePerformance/search?query=manual...
Then the (US ACCA) Manual S (select) to figure out your equipment:
* https://www.youtube.com/@HomePerformance/search?query=manual...
One can lookup the 1% (or 0.4%) of coldest/hottest days for your area, which would help determine what one actually has to typically worry about:
* https://ashrae-meteo.info/v2.0/
* https://www.airequipmentcompany.com/2021/what-does-design-da...
It's fine. The only difference when it's super-cold is that the air coming out of it isn't as warm, so the heating cycle stays on for a longer proportion of the time. But it keeps it 70°F inside no problem at all.
Mitsubishi's maintain 200%+ efficiency down to -4℉ (-20℃) and 150% down to -22℉ (-30℃) [1]. Only a few towns in the continental US get below that, and even those aren't going to get cold enough long enough to make it worth it an an all electric home to switch to your emergency electrical resistance heating.
Their capacity doesn't start dropping until you get down to 23℉ (-5℃), dropping to 76% at -13℉ (-25℃).
[1] https://www.coolingpost.com/world-news/study-proves-heat-pum...
What percentage of the (US) population gets temperatures like that? That's generally mostly IECC Zone 7 (though cold snaps in Zone 6) can happen:
* https://basc.pnnl.gov/images/iecc-climate-zone-map
ASHRAE—an HVAC organization—has data on the coldest and hottest days for areas so that you can design things for the coldest or hottest 1% of the year (4 hottest/coldest days):
* https://ashrae-meteo.info/v2.0/
I think that if you have an older, leaky/ier, less-insulated house you may need to 'brute force' heating your (probably older) domicile. But if you have a <4 ACH@50 air tightness, and reasonable insulation levels, a good portion of the US population could make do with a heat pump.
Mitsubishi publishes data were they have 100% heating capacity at -15C, which some models being 100% at -20C and -23C:
* https://www.mitsubishielectric.ca/en/hvac/home-owners/zuba
At -25C they have 80% capacity:
* https://www.mitsair.com/wp-content/uploads/2024/10/MEM-20240...
A lot? e.g. Chicago gets it every year
>> > What percentage of the (US) population gets temperatures like that? That's generally mostly IECC Zone 7 (though cold snaps in Zone 6) can happen:
> A lot? e.g. Chicago gets it every year
[citation needed]
Per historical weather data:
https://ashrae-meteo.info/v2.0/index.php?lat=41.960&lng=-87....
It is warmer than -16C/3F at Chicago (O'Hare) for 99% of the time (i.e., except for 4 days a year), and warmer than -18.7C/-2F for 99.6% of the time (2 days).
ASHRAE are the folks that publish the heating/cooling standards that are used in building codes for estimate heating/cooling equipment capacities (Manual J) and selecting the right equipment (Manual S).
Here's a PDF with a lot of locations in the US and CA (and other countries further down), and if you look under the "Heating DB" column, you'll find very few US locations that have -30F under the 99% (or even 99.6%) sub-columns:
* https://www.captiveaire.com/catalogcontent/fans/sup_mpu/doc/...
So unless you're in AK, MN, or ND, long runs of temperatures colder than -20F/-30C don't happen too often. Of course if you have a leaky house with little insulation, you're throwing money out the window/door, so the first consideration for a good ROI is better air sealing and insulation.
Also..
> It is warmer than -16C/3F at Chicago (O'Hare) for 99% of the time (i.e., except for 4 days a year), and warmer than -18.7C/-2F for 99.6% of the time (2 days).
If my heat doesn't work for those days, I'm kind of boned. Four days per year without a working heat pump? That's a mess.
Which is, of course, very expensive to use -- but it's only expensive for those 4 days. Resistive heat can be avoided for the other 361.2425 days in a year.
In the US (as of August of 2025), the average price of residential electricity per delivered kWh is $0.1762 [1].
If using resistive heat averages 4kW during each of those 4 days (it's probably either more than that, or less than that, but ballparks are ballparks), then that's about $16.92 for each of those days. Or: $67.66, per year.
Not so bad, right? Or at least, not "boned."
[1]: https://www.eia.gov/electricity/monthly/epm_table_grapher.ph...
The design philosophy for using 1% is that you may end up having to run your heating (or cooling) 24/7 to keep up with temperature delta between outside and desired inside, but it will keep up with the demand.
The rest of the time (99%) the mechanicals only run intermittently. Also note that the 1% would not necessarily occur every year: it is just the historical average. The charts also have the 0.4% extremes if you want to be extra conservative, but most building codes specify 1% because that is what experience has shown is a good trade-off.
Part of the process (in the US) is to use what is called the Manual J to determine/estimate/calculate how much energy is needed to maintain a particular temperature (typically ≥70F/21C in winter, ≤75F/24C in summer):
* https://www.acca.org/standards/technical-manuals/manual-j
* https://www.youtube.com/@HomePerformance/search?query=Manual...
> The Cooling Design Day is effectively the "worst case" day for your air conditioning loads. The "worst case" hour of this day determines equipment capacity, fan sizes, and subsequently duct sizes. This largely impacts first cost. The Design Hour also impacts peak KW demand which often has a huge impact on the utility bill.
* https://energy-models.com/blog/hvac-what-cooling-design-day
* https://hvac-blog.acca.org/sizing-selecting-hvac-equipment-p...
* https://www.airequipmentcompany.com/2021/what-does-design-da...
Here's an overview of the design process for one particular municipal jurisdiction:
* https://www.suffolkva.us/DocumentCenter/View/7362/Understand...
The choir's appreciation towards this unnecessary lesson is not very good.
I’ve had a gas furnace keep me and the water heated multiple times in a cold weather power outage.
If you have a backup generator, is it too small for your AC in the summer?
I would never use the generator in the summer though, doesn’t get that hot in the Pacific Northwest.
The major manufacturers have systems that will use the heat pump when the temperatures are not 'crazy', and kick in fossil at a certain point:
* https://www.trane.com/residential/en/resources/glossary/dual...
* https://www.carrier.com/residential/en/ca/homeowner-resource...
* https://www.lennox.com/residential/buyers-guide/guide-to-hva...
Depending on the cost of power and fossil fuels, you can program it to switch over once the COP becomes too low to justify running up kWh on your meter.
But whereas in the past heat pumps would have their COP drop around 40F/5C, modern systems can be fairly efficient at much lower temperature nowadays:
* https://neep.org/heating-electrification/ccashp-specificatio...
You have heat pumps running in Alaska:
* https://www.adn.com/business-economy/energy/2024/09/01/energ...
* https://alaskarenewableenergy.org/wp-content/uploads/2024/10...
Also the winters are mild here so basically everyone has either a heat pump or the further south you go it's just heat strips because heat is rarely used so not worth the cost.
So any kind of blanket statement about heat pumps vs gas heat would be folly, but due to improvements in cold weather heat pumps and solar power are allowing them to make much more sense in more places.
There are many advantages to decoupling fuel combustion from its energy use, burning NG at a power plant relatively efficiently with much better emission controls, then distributing on electric grid for use more than just heating, while allowing the home to heat from many different energy sources and allow for grid down backup as well.
https://www.eia.gov/dnav/ng/ng_pri_sum_a_EPG0_PRS_DMcf_m.htm
https://www.eia.gov/electricity/monthly/epm_table_grapher.ph...
The CoP is often around 2.0 at those very low temps, though (and of course the heat energy demanded is higher).
(It is more expensive to operate than the natural-gas furnace was, though).
Regarding cost, in most of the countries I've lived in a large fraction of the cost in the gas bill was the distribution cost. So once you switch to a heat pump, you also switch to electric cooking and even if heating with electricity would be significantly more expensive you would still win. Is that different in the US?
For September, $12.31 of my $27.01 gas bill was variable based on my consumption.
In December, $84.82 out of my $99.65 total was consumption driven.
I've run numbers on whether it'd make financial sense to go electric for heating, and the break even point is in the 30-40 degree vicinity. With temperatures 20 and under a healthy chunk of the year, unfortunately the added expense doesn't make financial sense.