And no matter what happens, customer support should help the customer, not blame them.
And no matter what happens, customer support should help the customer, not blame them.
- Mr MBA
What's most likely though is that the fuse is also internal, and externally the unit will appear bricked.
Usually a system would have a safety margin of at least 1.5x, or 3x or the like.
In this case the design safety margin appears to be…. 1x? Exactly?
In fact, they can.
"Voc 37v @ 25*C"
Vs
"Voc 37v"
Edit: Isc is the same- max current.
E.g. choosing a random Jinko datasheet: https://jinkosolarcdn.shwebspace.com/uploads/JKM600-625N-66H...
V_OC is specified at both STC and NOTC, and the datasheet clearly states which environmental conditions accounted for in those test conditions.
That is the issue is with the wrong labeling of things that are being plugged into this vendor's device, not the vendor's own labeling.
I agree the labeling is an issue here, but the solution must come from the wider industry or regulatory bodies; the alternative is for vendors to switch to their own pseudo-units to internalize the math, which would not be good for customers either - think "ACME Generator2000 accepts up to 4 Power Units of input; each ACME SuperEco Panel supplies 1 Power Unit, or 1.5 Power Units if you're in Canada...".
Saving users from having to do a little thinking to not brick their device is a tried-and-true excuse for vendor lock-in in our industry :).
Completely unhelpful to those that need the info.
Nobody seems to remember a bunch of companies receiving rather large fines for pulling known bull-crap "may contain sesame."
The label on the modules themselves tend to also provide these ratings at STC, e.g. this label from Jinko specifies the Open circuit voltage and also summarizes the conditions assumed for STC:
https://image.made-in-china.com/202f0j00LURcYuatWIqH/Jinko-M...
While I agree that the label could also add the temperature coefficient, I'm not sure if it's reasonable to expect that specialist electrical equipment details all of its operating parameters on an attached label without the expectation of consulting a datasheet or manual. For specific products that primarily target non-specialised consumers however, a different labelling approach may be warranted.
So given that in almost all use cases, you can have 2 panels in series, they should just say “max 2 panels in series”. Simple.
A good product hides complexity from the user with sane defaults and optional advanced configuration. This feels like the same problem.
As it is, panels are gonna produce variable power depending on the weather. Putting interoperability with third-party panels aside, to get the simplicity of "max 2 panels in series", they'd have to either cap the max power on the panel/generator link and dump the excess, or set the limit based on the worst case a customer is likely to encounter. I.e. they're either gonna waste power, or gouge their customers for extra hardware. Neither of that makes sense for an ecological product sold to a price-conscious customer base :).
"Wasting" those 5~10% during severe winter conditions isn't worth splurging on the voltage converter.
Though then selling units that suggest to not run a few hundred volt strings before paralleling instead does sound bad, as the string doesn't need separate fuses rated to many volts DC.
Idk. I don't have a PHD, but 220V sounds like 240V to me. I wouldn't do this.
I feel like getting advice about how to wire up electronics should not be so hard.
> Maybe they should just improve their product to make it more resiliant
Adding "resilience" usually adds to the per-unit cost. I think making a web page adds some cost too, but at least that can be amortised.
> And no matter what happens, customer support should help the customer, not blame them.
I think that's happening here: Making a web page to educate future customers seems like a really good idea. I wouldn't have thought that necessary until I saw it, but I'm always excited to learn something new.
The existing customers who did dumb should consider this a relatively cheap education in electronics; cheaper than a PHD at least!
Also, whether the company also gave them rebates or credits we don't know here, but telling "customer support" they "should help the customer" is also telling them they're not helping the customer, and you don't know that.
I don't think this is an official website of ecoflow.
Other than that I agree. I don't think asking for a bit of knowledge from the customers is a bad thing. A warning in the manual about safety factors should be enough.
In this case, the cost is much less than a dollar (say, a varistor that blows the existing fuse) and it prevents a catastrophic failure.
I have all sorts of electronics that say everything from 208V - 240V that all go in the wall, so I think all those numbers are probably close to each other in whatever a volt is.
I think if I'm worried about a limit of some kind, being within 5% of that limit seems like I might as well be over-limit if the commonly seen distribution I see in my house is greater than 15%
The margins are generally lower for higher power devices because the electronics are more expensive. Thankfully these electronics in general are becoming cheaper which is one reason why they’re ending up in the hands of people inexperienced with them.
Also try to tell someone they need an extra 30% in margin and often they'll think they’re being upsold.
I bet you also have a lot of electronics that don't though, and those that do probably say so.
My kitchen mixers, dishwasher, washing machine, driers, rice cooker, refrigerators, sauna, and pool pump aren't that tolerant by a long shot. I've got a few computers with a switch on the back to choose between 220v and 110v.
Plugging something that takes 110v into my house breaks the thing, so I've learned to check.
But I don't have anything that's 208v that can't go into the house. So I think whatever the situation is with volts, within 15% is "basically the same", so coming within 15% of the rated limit, is probably just like exceeding the limit by 15%.
And so this is why I would not expect something at 146V to be under the safety limit of 150V.
> Also try to tell someone they need an extra 30% in margin and often they'll think they’re being upsold.
Where do you get 30%?
People generally are not lugging white goods internationally, the average persons experience with different voltages is for laptop and phone chargers when they travel.
But for the matter at hand, the margin mentioned is needed on the solar systems, this is where the inverters can get expensive, which is why it can look like an unnecessary upsell to people who’ve never blown a device before.
Sure. I have high-powered and old things, and I bet you've seen stuff like that too.
I'm explaining why I, as a non-expert, would not put 146V into something that says it can't take more than 150V.
> People generally are not lugging white goods internationally
Travel doesn't enter into it; My appliances came from Europe, they're just labelled a bunch of different voltages, so I think voltages within that range are roughly equivalent.
Furthermore, British have such a very special relationship with tea, such it would be entirely understandable that a Brit would take their kettle with them and often become quite annoyed that they cannot get an adapter to use it when holidaying amongst the yanks.
Line-to-line voltage on a three-phase 208V system is 208V, line-to-line on 240V single-phase system is 240V.
Most commercial lighting products are rated for 120V-277V so they work on both residential and commercial (480/277V line-to-neutral single phase voltage is 277V)
220[Vrms] * 1.414 = 311[Vp-p] btw. HOW!?
So now for all 220/230/240 V standards you have the same maximum voltage value that is used for electrical designs (about 265 V effective), so they are equivalent, regardless of the name.
The actual maximum peak voltage for the European mains, is 230 V * 1.15 * sqrt(2), because of a 15% tolerance. That is about 375 V. With a small safety margin, the minimum voltage rating for components connected to 230 V a.k.a. 220 V is of 400 volt.
Yeah, this sounds very much like "you're holding it wrong".
And even for amps where you see that 80% rule, that's for keeping the load smaller than the supply. Solar panels aren't a load and don't work that way.
Typical house wiring is required to handle 600v due to voltage transients and wear and tear.
So any component rated to 240V dc will fail immediately on AC, and even 400-500V DC is not a good idea.
I guess there is a reason there is a whole category of engineers for this kind of thing.
I think if you work with electrical or electronic systems in practice, you learn pretty quickly to respect tolerances and that data sheets are a map, not the territory.
Also, electrical installations are usually seen as a field that should be done by trained personnel, not arbitrary laymen home owners. So I think the appropriate reaction would be to remind people that they should hire an electrician to do the installation, if they don't have the necessary specialized knowledge themselves.
Though the lines are often blurred, because I guess most companies would like to sell directly to end customers, even if their product requires a professional to install.
Even IKEA does this. You can go in and buy an electric stove and oven, grab them from the warehouse and take them home with you right there. But it's a bit of an illusion: You're still supposed to call an electrician to actually connect the things.
You can do that by just reading the product page[1]. The delta pro, the equipment in question, looks like a plug-in appliance. It visually communicates that it is portable (by having a wheel and a handle) and by virtue of having a power lead connect to it it communicates that you can just plug it in. They further reinforce this by writing this: "Plug & Play home backup solution". "Easy installation with completely pre-wired Plug & play home backup solution" "The solution provides a convenient home battery system without rewiring or running dangerous extension cables through your home." "Plug directly into an AC wall outlet and make sure that the wall output current is more than 15A."
And on top of that the manual[2] makes no mention of needing an electrician.
In contrast an IKEA electric oven's product page[3] states this: "No plug is included. Installation to be carried out by a qualified installer." and then the manual[4] states "Installation, including water supply (if any) and electrical connections, and repairs must be carried out by a qualified technician."
But of course nobody reads the manual. The big difference is that one comes with a plug while the other doesn't.
1: https://us.ecoflow.com/products/delta-pro-portable-power-sta...
2: https://websiteoss.ecoflow.com/cms/upload/2022/10/12/1312845...
3: https://www.ikea.com/gb/en/p/mataelskare-forced-air-oven-ike...
4: https://www.ikea.com/in/en/manuals/matalskare-forced-air-ove...
This world is amazing anything runs at all. The slightest addition of complexity is causing everything to fail now.
Modern computers are less reliable than ever, some companies have decided to REMOVE the pinhole bios reset (that has been around for 30 years) at the same time as things are buggier now and dont boot again until you physically unplug the bios battery deep inside and hard to get to.
It works! OK, stop touching it. We don't want to break it.
Whether or not the company in this case shares some or most of the blame with novice users - the analogy is not a great one.
https://interestingengineering.com/videos/1950s-reanimating-...
Unless it’s safety critical, you usually don’t want a system with a bunch of active electronics to prevent someone wiring it up wrong, because those components will interfere with whatever you’re hooking it up to, such as the MPPT, the battery, or whatever else.
This is like how AA batteries have a nominal voltage of 1.5V but the actual open circuit voltage is 0.9V~1.65V depending on charge level, temperature, etc. If you connect an AA to something that’ll explode at a voltage of 1.55V, that’s on you.
Similarly if you buy a 470 ohm resistor, you will find in on the data sheet that’s usually at 20°C. To know what it’ll be at any other temperature, you’ll need to use the temperature coefficient to calculate it.
You started off by saying you don’t know about the components they’re selling - but that turns out to be absolutely critical to understanding the context here.
Either way, I can’t believe they just let it fry the main board instead of having a sacrificial fuse or equivalent go first in these scenarios, whether it was a product aimed at professionals or not. It’s just dumb.
It's a main-voltage electrical system. I'm not even sure it would be legal for an electrician without the appropriate qualifications to commercially commission one of these systems. Their website even says installations should be performed by "a licensed electrician or a qualified professional."
In practice, every single solar system I've seen is exactly the same as this one.
A fuse wouldn't help here because they're current protection devices but we're talking about voltages here. Voltages are harder to generically protect against with a sacrificial device, and also over-voltage protection devices themselves have a habit of catching fire even when the voltage is within limits so you probably don't want one right next to your lithium batteries anyway. You'll even find most consumer devices don't have much in the way of continuous overvoltage protection.
It's typical when commissioning solar to just "protect" from panel overvoltage by ensuring your panel outputs are well within the margin of your MPPT (this device appears to be an a combined MPPT, inverter and battery) on a worst case cold day. Really there's just no reason to run your panels right up against the MPPT max voltage.
Given how easy it is to protect against design overvoltage by designing your panel circuits suitably, and how overvoltage protection devices are themselves a point of (potentially catastrophic) failure, I think it's pretty hard to make the case for including one as standard, which is why nobody does.
But leaving this particular issue aside, these devices are totally not suitable for consumer installations unless you like fires.
Essentially the "nominal" behaviour is not the actual behaviour, it's just a quick way of summarising the characteristics in a way that someone familiar with the class of item will be able to understand what they're buying. Another similar situation is timber sizing, where a 2" by 4" is actually 1.5" x 3.5".
In the case of electronic components, the actual behaviour will be either documented in a datasheet or just common knowledge in the industry. For example if you're buying a standard li-ion battery with no active circuitry, you'll often find the datasheet quite lacking in details because you are expected to just know the characteristics of the li-ion chemistry provided the basic parameters are provided.
So say, the input is rated for 150V, spec the components to sustain 180V, and trigger the MOSFETs to disconnect the panels at > 160V.
And maybe also add a big ass buffer capacitor, that can be used to soak up a bit more energy in the case of an inrush spike before the MOSFETs actually disconnect.
DC starts getting really nasty to deal with somewhere between 36-52v, with 150v of panels not being something joe-blow should be able to buy on amazon. Designing these systems to be safe is difficult.