I always thought it was somewhat fantastical. I'm rather delighted they could have beaded some polystyrene and stuck it in a cup for much the same effect.
Several SF novels mention using scintillation plastic. Is that also simply fantasy, or are there passive scintillation meters which could in fact detect levels of radioactivity? The 1900s models demanded 20 minutes of acclimatisation inside a dark chamber and were notoriously hard to use. Rutherford refused to use a counter while he could show his trained workers (women mainly) were as accurate. Those counters were photomultiplier tubes. I think quite a lot of the tech here was a precursor to TV, and ultimately the CCD in some ways.
Filmstrip exposure would tell you about a lethal dose, after the event. Helpful for budding scientists if they have enough lab rats to send out with a chunk of film in a wrapper.
Carefully carry it to the window overlooking the lower roof. Toss it on the roof. Let it evaporate.
One thing with scintillators though: You're typically detecting a few photons at a time, so a photomultiplier tube (PMT) is really required for any kind of reasonable SNR with any kind of reasonable temporal resolution.
> Those counters were photomultiplier tubes.
A PMT is actually not a counter (but they are normally used with a counter). It's just a transducer that produces electrical charge at the output in response to photons at the input.
Normally the PMT is connected to a "discriminator" (very fast voltage threshold detector, with adjustable threshold(s)) which takes the very narrow pulses (~2-3 ns) from the PMT and stretches them into pulses with fixed rise time, width and voltage. Those pulses are then counted using whatever hardware you can dream up.
A PMT is really just an electron multiplier with a photocathode in front, so you have all the same issues as you do with electron multipliers and thus use a discriminator for all the same reasons (mainly to remove "runt pulses" that didn't originate from a photon at the input window). Normally you'd use a single level discriminator, but "multi-channel" ones exist also.
Having an adjustable threshold on the discriminator is important to maximize SNR because the electron multiplier within the PMT will wear out and produce smaller pulses, and there can be significant variation in pulse size across serial numbers.
> Rutherford refused to use a counter while he could show his trained workers (women mainly) were as accurate.
I'm skeptical of this account, and the only thing I can find with a quick Google is that Rutherford hired women to count scintillation events because he could pay them less than men(-counters).
"I've held this thing up to the strongest sources of radiation I have and the balls don't budge... I think it's safe to say that if you do ever see the balls drop, you should run, not walk, to wherever you think there might be less radiation around."
https://theodoregray.com/PeriodicTable/Samples/094.4/index.s...
It has that feeling of hand spun websites from the aughts maintained with such care, like a curio cabinet. It's been a long time since I just clicked around one of these. There's a lot to be said for the simple and minimalistic designs that are more conventional today, and I'm going to continue laying out my HTML that way, but in comparison they're woefully lacking in character.
https://youtube.com/watch?v=3kHfXntPMoI
I think they would work as advertised. I'm not sure that makes them entirely not snake oil, though.
These days digital integrating radiometers are able to not just integrate dose over time, but also adjust for dose rate effects (i.e. same amount radiation absorbed over shorter time is more harmful), and ratio of beta, gamma, and neutrons. And they cost in the range of $200. I still keep my CD V-715 somewhere in the closet, though.
I can imagine it now:
"I can now afford to buy a device that will inform me if I'm about to die"
https://patents.google.com/patent/US3093737A/en?oq=3093737
According to the patent Walter Shriner was based in Springfield, Illinois, which was mentioned as "ground zero" for these devices.
Shriners patent references the older 568 patent by Failla, who assigned it to the Atomic Energy Commission.
Does this detector work equally well?