Everyone rolls their eyes at me when I say this, and for some reason no one has seen such installations, nor heard of anyone doing them. Am I crazy or what?
(And yes, if I ever build a house, I'll make sure to add Jefferies tubes!)
Everyone rolls their eyes at me when I say this, and for some reason no one has seen such installations, nor heard of anyone doing them. Am I crazy or what?
(And yes, if I ever build a house, I'll make sure to add Jefferies tubes!)
Plus, this does not solve the problem of the starting and ending segments of cables, that just go vertically through tight holes bored in the wall.
That looks rather OK for my tastes. And is simple to implement, up to 1Gbit/s. Not because of the limitations of the cables, they go up to 40Gbit/s in flat form factor, but for the small switches, or SBCs which could be 'abused' as such.
Anyways, Nanoleaf or any others don't come ready for POE, so have to be modded, but not by much. Controlling them over ethernet requires more modding, but not that much either. One could also use the remote, and just give power over POE.
More generally I'd like modern houses to have more 'wet walls' like they had in the Matrix, where there's a space big enough for a worker to actually maneuver between rooms. Problem is that's also a space pests and fire can move.
If You have never used Panduit, choose wisely the room where it initially is installed. Start off with the lab or workshop or under kitchen cupboards (ie, places where the other half isn't going to get bothered by it). Also, it helps if the area has many semi-permanent cable runs ("this extension will only be here for a few days..." - unintentional fib). Personally, every time I install a new rack or mounting board (think 1m x 2.5m board on a wall to hold tools or "temporary" power strip/network equipment/test fixtures), I put in a length of F2x3 "narrow slotted duct". I use much smaller under the cabinets. The larger ducts are good for hiding the extra cable length so only what is needed escapes the enclosure.
Initially, it is often ugly. I would not want to live without it. Bonus points for creative mounting (the other half still has not noticed the piece across the lower back of the upright piano but has noticed the lack of cables).
Uh, what? Why are you telling people to violate the NEC? Do not use strut as a raceway, why would you suggest that? It’s way more expensive than a UL listed raceway, and not suited for raceway purposes anyway.
For surface mounting, use a listed surface mount raceway: https://www.legrand.us/wire-and-cable-management/raceway-and...
Legrand makes many different sizes of surface raceway.
If you want pathways inside a wall, use a listed conduit (PVC or EMT), if you’re fishing into existing walls you can make sleeves out of EMT or PVC (drill a hole and slap bushings on both ends)
So that works like you suggested, but is a bit ugly.