Yes, the average person can do it, but many won't. And it will be innocent bystanders or firefighters or whatever that pay the ultimate price, not the sloppy guy or gal that saved a few dollars by doing it themselves.
I wish that our building codes and permitting system had provisions for "competent amateurs", but how on earth would you do that?
What does this mean? Any “amateur” is allowed to do the work anytime they want (on their own home), and anyone can apply for a permit. They just have to pass the same inspection as everyone else. I do not see why the code (rules) would be different though, the principles of electricity and safety do not change.
This is not true across all US states, let alone other countries.
I currently live in a jurisdiction that does allow home owners to do their own electrical work, but they have to pass a (demanding) exam before being licensed to do so. In my previous home state, home owners were not allowed - even if you did the work, a licensed electrician had to be "seen to be responsible".
Which states do not allow DIY electrical? A quick search is not coming up with any examples.
Putting in a new panel can get you more space, or just update to a currently maintained standard for breakers so you can find and put new ones in.
It sounds like he was adding circuits which means he's running wires for those new circuits anyway.
As long as you you use a panel that accepts the same type of breakers, you can also re-use the existing breakers, unless code require upgrading to AFCI breakers. Otherwise you swap them for new breakers of the same rating. (Assuming the US: There are some inspectors who would ok a panel swap that reused the existing breakers without requiring upgrades, but technically upgrading is supposed to be required, unless your state amended out the AFCI requirements in the state version of the code). Note: technically many breakers can fit in competitor panels, but they are not legal. They were not designed nor tested to trip at proper ratings in those panels, and using them violate the labeling of the panel.
Now obviously the reason for upgrading the panel is to add more circuits, and it is possible that these additional circuits if added would need more power than the 100A service can provide. To technically comply with code, you need to follow the rules to calculate the expected loading of existing circuits plus planned new circuits.
The last sentence you wrote is the killer. You are technically correct that changing the number of circuits in the panel is not itself disallowed. But .... you would also be hard pressed to get an AHJ to pass a number-of-circuits upgrade without knowing how many circuits you are planning on adding, and doing the feed sizing calculation to make sure you don't have to upgrade the incoming feed to support it.
I really don't like MWBCs myself, if I would've known the electrician for my house was going to utilize a bunch of them, I'd have happily paid him not to do that.
I live in a small town in Michigan; the amount of fuss probably depends on location & density.