When using the ungrounded adapter, the entire case of my 2011 MacBook Air and the iPad 2 got slightly "spicy", although it felt more as if the case suddenly changed texture and was more wavy (probalby an artifact of europes 50Hz mains frequency).
The strangest thing was turning on my touch controlled desk light while working on the laptop. If I touched the light and the laptop at the same time, the light shocked me quite noticeably.
Instead one wire is neutral, one is phase, and the third, optional, is ground.
In the US there is one neutral and one hot line. Then there is the ground that is grounded at the box preferably. You can sometimes have a 240 line split to feed two 120 outlets where the hot lines from each are at a 240 difference to each other. If one line has a large load relative to the other, the neutral won't be that close to ground. Is that was is happening with these laptops?
Shouldn't it still be pretty close voltage wise? If we hold the neutral is always at 0v at the panel, since that's where it's tied to ground, the voltage on the neutral between the panel and the outlet should still be pretty low because copper wire has a pretty low resistance (by V=IR). I'd have to break out my calculator (and look up the actual standard values of copper wire resistance), but I'd guess even >20V would be quite unusual without some other fault...
Because it can cause power to go unexpected ways.
All the "power safety" stuff does nothing if everything is correct and perfect, but if it fails, and ground and neutral are bonded anywhere EXCEPT at the panel, you can get power flowing through you.
I measured the voltage difference and, if I recall correctly, it was something like 20V. I started using the 3-prong adapter and haven't had any more issues.
In many places electrical wiring in homes is just two wires and what wiring monstrosities await you in shabby clubs and shady rehearsal spaces is just beyond belief. Be safe.
However the electrical wiring for my apartment is only about 20 years old...
Edit: MertsA added some more info below: https://news.ycombinator.com/item?id=33572585
If I replace the direct corner adapter of the brick with an older (from a 2015 MBP 15) extension which is grounded, i.e. you can't then literally plug the charging brick directly into the power socket, there's an "extension" chord in between (and not just a generic one, this is Apple specific for the connector to the brick), the issue goes away.
No other symptoms though.
Shouldn't be able to hurt you THAT much ...
Thanks a lot for you comment. I had noticed that myself with two old Mac Book Airs.. Actually, that's how I knew if plugs were grounded or not: I could immediately tell.
But, over the years, I always wondered if there were any electrical issue (in several houses) or if it was normal.
This isn’t a building wiring issue.