Take a look at the Spec for a valve from Rainbird:
https://www.rainbird.com/sites/default/files/media/documents...
Electrical Specifications:
• Power: 24 VAC 50/60 Hz (cycles/second) GBS25 Solenoid
• Inrush Current: 0.41 A (9.84 VA)
• Holding Current: 0.20 A (4.80 VA) at 60 Hz, 0.23 A (5.40 VA) at 50 Hz
If you have a sprinkler system, you can replace the on/off valve with a solenoid valve and then you're able to control the system electronically using a 24 VAC power supply and a switch. The OP replaced the switch with a relay, which is a switch that can be actuated by the lower voltage from something like a microcontroller.
as long as you don't run several at once, can power from old wall wart with a few amps rating. I'm using a meanwell PSU so I can power a few other things - IR lights mostly