At the lowest level there are three RAID groups in each pod. Each RAID group is made of 15 drives configured in software RAID 6 with 2 parity drives. This means you can lose 2 dives and the data is entirely safe and intact. If 3 or more drives completely fail simultaneously (not just pop out of the RAID group or power down, but where that drive is lost forever, like it will never power up again) you will lose at least some of the data on that RAID group. Layered on top of the 15 drive RAID group is LVM. The specifics of the LVM config are there is one PV (Physical Volume) spanning the 15 drives, then on top of that are one VG (Volume Group) spanning the same exact 15 drives. Then on top of that are as many LV (Logical Volumes) as it takes to keep each logical volume under the ext4 limit of 16 TB. With 3 TB Hitachi drives, there are 3 separate LV on top of the same exact 15 drives. Finally, there is one ext4 file system sitting on top of each of the LV (one to one with the LV). Disclaimer: I work at Backblaze, but datacenter and pods aren't my main area of focus.