Obviously their "solution" was lethal. But the original presumably safe design seems impractical at best.
Obviously their "solution" was lethal. But the original presumably safe design seems impractical at best.
> Analysis of these two details revealed that the original design of the rod hanger connection would have supported 90 kN, only 60% of the 151 kN required by the Kansas City building code. Even if the details had not been modified the rod hanger connection would have violated building standards. As-built, however, the connection only supported 30% of the minimum load which explains why the walkways collapsed well below maximum load (Feld and Carper, 1997).
(my emphasis)
http://anengineersaspect.blogspot.com/2009/07/the-28th-anniv...
I worked in a gear shop for 5 years, yes, threads that long can be done. I suspect it might have been cheaper to get a rolled thread in that length, rather than a cut thread. Rolled thread is likely to be stronger, as it is formed, and not cut.