> No electricity = no heat, regardless of natural gas supply.
You're confusing furnaces and fireplaces.
A fireplace is soemthing that sits in a living space usually with a visible flame behind glass and is designed more for aesthetics than function. They typically run using a millivolt valve for the gas supply, with the voltage generated from a thermopile sitting in the pilot flame. They're often controlled by a regular light switch or a simple two-wire mechanical thermostat.
There's natural gas and propane models, and they'll run so long as you have gas flowing.
I upgraded mine to use an older wifi thermostat, but kept a light switch on a small cable underneath so I could always use it in case of a power outage, and it's come in handy a couple times. [1]
Mine also has a mains-powered blower fan built in (that's the plug on the left), but electrically it's completely separate and controlled by its own thermostat. It turns on when a certain temperature is hit -- usually about 5-10 minutes after the fireplace is on -- and stays on for some time after the flames are off. Obviously the blower doesn't work when there's a power outage but the fireplace still generates a usable amount of heat for the room.
On the other hand, my gas forced-air furnace -- which distributes heated air via ducts around the house -- is, as you describe, entirely useless without electricity. Even if it was running without the main blower fan, it would just be heating up the air sitting in the duct coming out of it. At best it might get some heat into the house via convection but I suspect it would cut out on thermal overload before actually doing anything useful.