Decoding Utility Markings Spray-Painted on City Streets
99percentinvisible.org
99percentinvisible.org
https://www.amazon.com/dp/B018CH0MX2
Definitely something I had never really thought about until recently.
c.f. https://en.wikipedia.org/wiki/Underground_Service_Alert
https://www.plateandlocate.com/article/1/name/Buried-valves-...
http://metricviews.org.uk/wp-content/uploads/070-rc.jpg
was what I was expecting. Glad they've gone metric and modern.
A typical one, is the indication (on the drawing) that a cable is 30 cm from the border of the sidewalk, but in the - say - 30 years since that cable was laid down the sidewalk has been enlarged by 40 cm AND a new cable has been laid down at 30 cm from the new sidewalk AND this other new cable has not been added to the drawing (or it has been added to another drawing by mistake).
So you go there, actually find "a" cable 30 cm from the sidewalk, believe in good faith that it is the one on the drawing, and next minute you cut the one now under the sidewalk.
It is only a few years that GPS positioning is used for cable and pipes layout (which should give better "absolute positioning") but the issues about mis-labeling and mis-reporting (given also the number of different companies, particularly telecommunications ones that may lay new cables) have not changed much AFAIK.
We once had a set of bored piles (Ø 1000 mm) for the foundation of a sustaining wall miss a high pressure large diameter (Ø600 mm) methane pipeline by millimeters (the drilling rig bit the steel pipe covering, making the actual metal of the pipe shiny).
The explanation was that the people making the drawing and maintaining the pipeline took as reference the milestones of the road (that were replaced because a curve was added some kms before and shifted by 100 m) and gave our project the green flag because we were almost 100 m away from the pipeline.
And yes, They are!
https://www.cornerstoneprojects.co.uk/index.php/blog/undergr...
I have a client who does groundworks and they always know when there's supposed to be something down there. You use the detectors to double check not as your only source. There could be something down there that's old and not on the registry or that HV power cable could be a few feet to the left of where it's supposed to be.
When you're the man taking a circular saw to the pavement and your boss is the one paying for the repairs, you check!
If digging needs to intersect any of those areas it generally means doing it by hand.