I'm not endorsing it, just posting, i have not yet see the video.
Where did you find that? All I could find is "0.8-1.8kW/hr" for a machine with capacity with a capacity of "30gal/day". This is complete nonsense, "kW/hr" is neither energy nor power nor energy per volume of product. And if it's power, why does it vary?
I'm going to read it as 1.8kW, with a capacity of 30 US gallons (113l) per day. My dehumidifier from the hardware store consumes 0.2kW at a capacity of 10l per day. They are 15% more productive... hardly a quantum leap.
It varies, as does output, because (as the numbers mention) this all varies wildly by atmospheric temperature and humidity.
(By the way, running the numbers I'm seeing it as 62.77L/kW vs. 50L/kW, which is a 25% improvement, though at much larger scale.)
So when they write kW/hr, they mean kWh/h, which is kW, because they expect readers to be confused. But if that's the power of the machine, it shouldn't vary. Just like my car produces 70kW, not "7-70kW/hr depending on road conditions". This machine would run a max power all the time, wouldn't it?
> 25% improvement
Serves me right for trying to compute in my head. Qualitatively, it makes no difference, though: they claim a 100% improved efficiency over the competition, and they are nowhere close. The 25% difference may indeed be purely to scale; bigger machines (whether from this company or the hardware store) tend to be more efficient.
Chilling below the dew point doesn't add much, if any, performance.
(And yeah, that kW = kW-h convention hurts my brain.)
Power consumption doesn't depend on humidity. Capacity does. So if they quoted "0.8-1.8kWh/l", that would make sense (but be ridiculously low). If they quoted 1.8kW and 40-100l/d, that would make sense, too. But 30gal/d and 0.8-1.8kW implies that the machine throttles the compressor in order not to exceed the advertised capacity, which it doesn't reach under real world conditions anyway.