So the difference between "electrician installed" and "mysterious, unknown person installed" is only in the finished product.
So the difference between "electrician installed" and "mysterious, unknown person installed" is only in the finished product.
I'm not an electrician so correct me if I'm wrong, but for those unfamiliar with residential wiring in US homes, ordinarily homes are supplied with two out of phase 110VAC lines. Heavy appliances like electric clothes driers and electric car charging points use the 220VAC that I available between the two "hot" lines. Everything else in the house use either one of the "hot" lines (black wires according to the national electrical code). There are actually 3 wires going to each outlet, light, etc. though the house: one black (belonging to one of the two sources of 110VAC), one white (called the neutral line, approximately 0V above ground, and one green a separate green wire that is connected to ground around the point where power enters the house.
Fundamentally, the power grid is based on three phase power. Typically, the average telephone pole will have four power wires on it, and one or two thick bundles of phone line or maybe cable TV, I dunno. Three of those four power lines are the three phase electricity, and the fourth is the common neutral line that is ideally near 0V, but typically fluctuates a bit.
Only three out of those four lines enter your house. One is is the neutral line, the other two are just two of the three power lines. Those two power lines are not 180 degrees out of phase, they are 120 degrees out of phase. If they were 180 degrees out of phase, the math is simple: it's obviously just 240V. Since it's 120 degrees out of phase, you end up with a sine wave that looks something like 120\(sin(x)-sin(x+pi\2/3)). (only you need to adjust it for frequency) If you're better at your trig identities than I am, you can calculate that out exactly, but for simpletons like me I just plug it into my calculator and find a local maximum of 207.846 something.
(note: In the US, we use neutral and ground to refer to the common center of the three phase power, and the wire that is buried in the ground near your house, respectively. In the UK, I think they call these two wires ground and earth, respectively. Note that the term "ground" has a very different meaning (read: one of them can kill you, the other one keeps you safe) depending on the context.)
The few houses that I was involved in wiring of in the states were definitely "split phase" systems, which work like the GP describes. In those, three current-carrying wires come from the transformer - two ends and a centre tap from one winding. Those are wired in the breaker box so that the house has two circuits that are 180* off from each other, giving 110V on either circuit, or 220V between the two "hot" legs. There's a better description at https://en.wikipedia.org/wiki/Split-phase_electric_power.
Two of the phases DO NOT run to the house, a typical US household service is split-phase. The primary winding in the transformer at the pole connects between a single phase and ground, and the secondary winding is center-tapped to provide a 'neutral', with 120v on either side of the neutral. The voltages are indeed 180 degrees out of phase.
Your test would show 220-240v in the vast majority of US-based residential situations.
The 120/208 you are referring to is when all 3 phases are fed in to a WYE transformer that has 3 120v secodary windings fed from a center point, which becomes the neutral. With a WYE transformer, each phase gets 120v to ground/neutral, and the phase-to-phase voltage indeed peaks at 208v due to the 120 degree rotation between phases. This is typically only found in large residential(600+ amps), and medium to large commercial and industrial buildings with 3-phase service.
Another method would be using a 'Delta' transformer, in which one of the phase-to-phase windings are center-tapped, similar but a little different than the single-phase residential service. The two phases on either side of that center-tap will be 120v to neutral, but the 3rd phase will be 208v to netural/ground. This is usually called the 'wild' leg and is often used to power lighting loads.
Source: I've been doing this for a long time.
Also https://www.doityourself.com/forum/electrical-ac-dc/549775-l...
And https://ctlsys.com/support/electrical_service_types_and_volt...
The current for the same wattage will be roughly double in North America. So lamps, etc. intended for use in Europe will have wiring that is undersized for the current draw if used in North America.
We found exactly that, lamp cords and extension cords, when we started our remodel a month ago. The former owner did some renovation ten years ago, and was an architect so we always assumed he did a decent job. That was one of a few questionable choices he made, so we're now re-wiring the entire house.
An organisation called TechSafe[1] is charged with carrying out random inspections.