Things I Won’t Work With: Dimethylcadmium (2013)
blogs.sciencemag.org
blogs.sciencemag.org
http://blogs.sciencemag.org/pipeline/archives/category/thing...
It is, of course, extremely toxic, but that’s the least of the problem. It is hypergolic with every known fuel, and so rapidly hypergolic that no ignition delay has ever been measured. It is also hypergolic with such things as cloth, wood, and test engineers, not to mention asbestos, sand, and water-with which it reacts explosively.
http://blogs.sciencemag.org/pipeline/archives/2008/02/26/san...
I Googled the ISBN of the quoted book by Clark "Ignition" and found a PDF copy online.
http://library.sciencemadness.org/library/books/ignition.pdf
http://blogs.sciencemag.org/pipeline/archives/2013/04/05/chl...
It will "literally explode if you move it, touch it, disperse it in solution, expose it to x-rays, expose it to light, and even if you did absolutely nothing to it." [1]
[1] http://pipeline.corante.com/archives/2013/01/09/things_i_won...
Liquid N2 is held in a dewar, consisting of an internal and an external tank with vacuum in between. In case of overpressure, there are blowout valves, designed to relieve pressure in a large hole rather than a small one. You'd rather have a large hole because a high pressure tank with a small hole is basically a rocket. Or a grenade. Also, the N2 liquid to gas expansion factor is roughly 1:700.
In any case, some special person at Texas A&M noticed a N2 dewar with a presumably damaged overpressure blowout valve and fucking welded a brass plug in place. Eventually, the tank catastrophically failed, most likely due to corrosion of the internal tank, leading to temperature increase and the aforementioned 1:700 volume increase. According to I believe the tank manufacturer, the tank mechanically fails at 1200 psi. When it finally went boom, it shredded the room it was in, put a 24-in hole through a concrete floor, significantly damaged a concrete/steel support beam, and was eventually stopped by a 3-in water main and other stuff in a mechanical room. Miraculously it went at 3-am or so and no-one was present.
When people determined what had happened, some unlucky dude who didn't get paid nearly enough got to frantically inspect every tank in the chemistry building to see if the mystery welder had "upgraded" any others.
There's a report pdf somewhere on the internet that I can't find at the moment.
I may have some details wrong but the boom part is definitely right =P
edit: https://web.archive.org/web/20060901094515/http://finance.ta...
it's worth looking at the pictures in the pdf
I wanted to share the story about environmental's efforts to put gas meters on the safety release valves on our large liquid argon dewars, but we thankfully convinced them that accidentally blowing a crater in the plant was a worse OSHA violation than upsetting our local regulators. (An accident in a nearby county with a truck hauling liquid gas dewars resulted in a death by displacing all the air in the intersection with Argon, leading the inert gas to be classified as a dangerous controlled substance that needed to be monitored and metered...)
The plug wasn't welded, it simply screwed into existing pipe threads replacing an overpressure valve.
=> that concrete roof probably had more to do with the stopping than the pipes below it.
I'm lucky to still be alive!
2) What sort of personal protective gear do you have to use?
2) Not enough. Respirator, coats and gloves.
For example, you can play with mercury. You definitely SHOULD NOT, but it won't kill you. On the other hand, dimethyl mercury WILL kill you.
exposure to only a few drops of the chemical absorbed through the gloves proved to be fatal after less than a year.